Testing: Bumperite vs. Traditional Wire Ties

Tests Conducted on Bumperite Waterguards

1. Peak Load Capacity - Smith-Emery Laboratories, Los Angeles, California

Test Performed

Conduct three successive tests to measure the average peak load in pounds of Bumperite Waterguard Sealable Scaffold Ties. Measure safety factor by dividing average peak load by four (4).

Bumperite pull test slide one.Bumperite pull test slide two.

(Welded Steel Anchor)(Peak Load)

Results

Test #1: 22,552 lbs.
Test #2: 28,685 lbs.
Test #3: 28,344 lbs.

Total: 79,581 lbs
Average Peak Load: 79,581 lbs divided by 3 = 26,527 lbs.
Safety Factor: 26,527 lbs. divided by safety factor of (4) = 6,631 lbs.

2. Water Intrusion - Smith-Emery Laboratories, Los Angeles, California

Test Performed

ASTM E331 -00: Standard test method for water penetration of exterior windows, skylights, doors, and curtain walls by uniform static air pressure difference. Sprayed with continuous water for 15 minutes with 15 lbs of negative pressure.

Bumperite water intrusion test slide one.Bumperite water intrusion test slide two.

Results

48 hour test with 2" of water. No leaks.

Bumperite water intrusion test slide three.

LOGO_-_image002

SIMPLE TO USE AND COST EFFECTIVE SYSTEM TO SECURE SCAFFOLDING TO YOUR PROJECTS!

test-_image004 test-_image006

test_-_image008 test-_image010

Water tested to ASTM E 331-0 & ASTM E1105-00 by Arhitectural Testing, Inc.

15 Lbs of negative pressure for 15 minutes

Report No. 90353.01-701-43

NO LEAKS!

WHY RISK MOISTURE INTRUSION IF YOU DON'T HAVE TO.

24 Hour Test With 2" of Water. No Leaks

testing-_image004 testing-_image006

testing-_image008 testing-_image010

Peak Load Capacity Testing Conducted on Conventional #12 Black Annealed Wire Tie Assemblies

Test Performed

Conduct three successive tests to measure the average peak load in pounds of competitors' scaffold ties. Measure safety factor by dividing average peak load by four (4).

Results

1. Red Head tie wire high-v-eye pin 3/16"shank x 1-1/2"

Red head pull test slide one.Red Head pull test slide two.

Test #1: 647 lbs.
Test #2: 718 lbs.
Test #3: 673 lbs.

Total: 2,038 lbs
Average Peak Load: 2,038 lbs divided by 3 = 679 lbs.
Safety Factor: 679 lbs. divided by safety factor of (4) = 170 lbs.

2. Tomarco AB90 Fastener clip with 1/4" X 1-1/2" wedge anchor

Tomarco pull test slide one.Tomarco pull test slide two.

Test #1: 875 lbs.
Test #2: 914 lbs.
Test #3: 942 lbs.

Total: 2,731 lbs
Average Peak Load: 2,731 lbs divided by 3 = 910 lbs.
Safety Factor: 901 lbs. divided by safety factor of (4) = 228 lbs.

3. Kwik-Bolt Tie wire wedge Anchor 1/4"x 1-1/2" embedment

Kwik-bolt pull test slide one.Kwik-bolt pull test slide two.

Test #1: 709 lbs.
Test #2: 672 lbs.
Test #3: 733 lbs.

Total: 2,114 lbs
Average Peak Load: 2,114 lbs divided by 3 = 704 lbs.
Safety Factor: 704 lbs. divided by safety factor of (4) = 176 lbs.

4. Tie wire split wedge Anchor 1/4" x 1" embedment

Tie Wire pull test slide one.Tie Wire pull test slide two.

Test #1: 644 lbs.
Test #2: 769 lbs.
Test #3: 876 lbs.

Total: 2,289 lbs
Average Peak Load: 2,289 lbs divided by 3 = 763 lbs.
Safety Factor: 763 lbs. divided by safety factor of (4) = 191 lbs.


BUMPERITE WATERGUARDS

Sealed with one component

Bumperite Waterguards are sealable with one component.

Traditional Wire Ties

Difficult to seal with two components

Traditional wire ties are not sealable.

Testing at Smith-Emery Laboratories reveal that the Bumperite Waterguard peak tension load is MANY TIMES STRONGER than conventional attachments.